Mil-RamOxygenSpecifications

  • Sensor Technology:  Electrochemical
  • Detection Range:  0.0 - 25.0 %Volume (other ranges available)
  • Resolution:  0.1 %Volume
  • Response Time:  less than 30 sec. 90%
  • Recovery Time:  less than 30 sec. 10%
  • Temperature Range:  -15 deg. C to +40 deg. C
  • Humidity Range:  15 - 95% RH, non-condensing
  • Pressure Coefficient:  0.01 %signal/mBar
  • Power Requirements:
       Model TA-2100:  12-30 VDC 1.08 W (24 VDC)
       Model TA-2102:  12-30 VDC (20 mA max.)
  • Outputs:
       Model TA-2100:  4-20 mA (Standard), Modbus RTU Option, Relay Module Option
       Model TA-2102:  4-20 mA Standard
  • Certifications:  CSA/UL Hazardous areas Class I, Division 1 GR B,C,D
  • Sensor Service Life:  >12 months typical under normal operating conditions
  • Accessories:
    Splash Guard, Cal Cup, Flow Cup, Duct Mount Kit, Pole Mount Kit, Sensor Extender Cable, Cal Kits, Gas Regulators, Sun Shade, more