GX-6100 Portable 6-Component Gas Detector- SPECIFICATIONS

GX-6100 Portable 6-Component Gas Detector—SPECIFICATIONS
by RKI Instruments

Sampling method

Suction type/Double type

Principle of detection

New Ceramic catalytic Method, Hot Wire Type Semi-Conductor Method, Thermal Conductivity Method, Non-Dispersive Infrared Method, Potentiostatic Electrolysis Method, Photo-Ionization Detector

Detection range

Depends on the target gas.

Alarm setpoints

Depends on the target gas.

Type of alarm

Gas alarm / fault alarm / panic alarm / man down alarm

Display of alarm

Blinking lamp / buzzer continuous modulated sound /
gas concentration display and blinking alarm details/vibration

Explosion-protected construction

Flameproof enclosures and intrinsic safety

Explosion-proof class

ATEX: Ⅱ 1 G Ex da ia ⅡC T4 Ga / Ⅱ 1 G Ex ia ⅡC T4 Ga
IECEx: Ex da ia ⅡC T4 Ga / Ex ia ⅡC T4 Ga
*The temperature class is T3 when using the BUD-6100
with Duracell (MN1500) batteries.

Ingress proof rating

IP67

Approvals

Japan Ex, ATEX, IECEx, Brazil Ex

CE marking

EMC / ATEX / RoHS / RE

Power source

Lithium-ion battery unit (BUL-6100) or
dry battery unit (BUD-6100) (AA alkaline batteries × 3)

Continuous operation

Approx. 28 hours (25ºC, no alarm and no lighting) [Lithium-ion battery unit]
Approx. 8 hours (25ºC, no alarm and no lighting) [Dry battery unit]
*Continuous operating time varies depending on the sensor installed.

Dimensions

Approx. 70 (W) × 201 (H) × 56 (D) mm (projection portions excluded)

Weight

Approx. 500 g [lithium-ion battery unit]
Approx. 450 g [dry battery unit]

Operating temperature range

-20 to +50ºC (no sudden changes)

Operating humidity range

0 to 95% RH (no-condensing)

Target gas
CH₄, Cl₂, CO, CO₂, H₂S, HCN, i-C₄H₁₀, NH₃, NO₂, O₂, PH₃, SO₂, VOC