| Sensor Type |
Integral Accelerometer |
|---|---|
| Sensor Frequency Range |
1 to 2400 Hz |
| Sensor Sensitivity |
10 V/g |
| Sensor Attachment |
Integral Magnet |
| Sensor Material |
Aluminium |
| Sensor Ingress Protection Rating |
IP68. Submersible. |
| Sensor Operating Temperature |
14ºF – 140ºF (-10°C to +60°C) |
| Sensor Physical Dimensions |
104mm (high) x 59mm (diameter) |
| Sensor Max Total Recording Time |
180 seconds |
| Sensor Data Memory |
32MB static RAM |
| Sensor Communications Type |
Optical |
| Sensor Communications Rate |
2.5 Mbits/sec |
| Sensor Power Type |
Dual Lithium Cells |
| Sensor Battery Replacement |
At factory or service center |
| Sensor Operating Time |
>5 years (when standard programming used) |
| Number of Epochs |
1, 2, or 3 |
| Ephoc Duration |
60 seconds |
| Sampling Rate |
4860 Hz |
| Sampling Resolution |
24-bit |
| Host Communication Type |
USB |
| Power Supply Type |
User replaceable alkaline 4 cell pack |
| Physical Dimmensions |
8 logger Case: 410 x 325 x 172 mm |
| Case Material |
Rugged, high-impact plastic |
| Case Ingress Protection Rate |
IP65 |
| Case Operating Temperature |
-10°C to +60°C |