Alarm Log Storage User configurable, defaulting to 200 alarm events
Audit Trails User configurable, defaulting to 200 audit events
Certifications/Compliance CSA/C-US Class I, Div 1, Groups B, C, D; ambient temperature range of -40°C to +85°C (-40°F to +185°F), temperature code T6 (-40°C to 75°C) T5 (-40°C to 85°C) EN 61326-1: 2013 (Industrial Criteria); FCC 47 CFR Part 15, Subpart B; ICES 003: 2016; Measurement Canada pending
Data Memory 2 MB Static Random-Access Memory (SRAM)
Description 3800 XP – MVT / Flow Computer for Gas and Liquids
Diagnostic AGA 10 Speed of Sound (Comparison with GC SOS Prediction)
Differential Meters (DP, Orifice) AGA 3/ANSI/API 2530-1992 Method 2; AGA 3/ANSI/API 2530-1985; ISO 5167 pt5; DP Cone meters; Averaging Pitot; GOST: Venturi Meters – Steam Flow IF97
Display 128 x 65 backlit LCD display; user-programmable scroll list and menus
Enclosure Rating NEMA 4X/IP67
Energy AGA 5; GPA 2172; ISO 6976
Ethylene Density Calculation API 2565 (Ch 11.3.2.1); Ethylene NBS 1045
Input Power 10 VDC to 30 VDC
Keypad 4 IR sensors through glass key input. (hazardous area isolation method).
Linear Meters (Turbine) AGA 7; AGA 9; AGA 11
Live Density Input Sarasota liquid density meter, Solartron, UGC, 4-20mA & density meters.
Operating Humidity 0-95% RH (non-condensing)
Operating Temperature Range -40° to +185°F (-40° to +85°C)
Processor 32-bit
Program Memory 4 MB of flash memory
Propylene Density Calculation API Ch 11.3.3.2
Super Compressibility (Fpv) AGA 8 Gross-1992; AGA 8 Detail-1992; AGA 8 Short-1988; NX19; NX-19 Analysis; GERG (ISSN 0178-9414 -2004/8 – European Gas Research Group)
Turbine Meter Linearization 10-Point Frequency/K-factor Table
Volume Correction Factors Consistent with API 2540/ASTM D1250-80/IP 200; 5/6 A/B; 23/24 A/B; 53/54 A/B; 6/24/54 C; CH 11.1 2004; Note: natural gas liquids (NGL) and liquefied petroleum gases (LPG): OLD 23/24, OLD 53/54; (Note: Table E is new standard to replace the Older version 23/24)