Humidity & Moisture
Product Categories

Very robust and highly insensitive to pollution. Measurement range up to 20 m/s (4000 ft/min). Voltage or ModBus RTU output.

A compact humidity and temperature probe with excellent price/performance ratio, optimized for OEM applications.

Digital two-wire output and the interchangeable plug-in design makes this probe ideal for OEM applications. Customized modifications such as different dimensions are possible.

Excellent accuracy down to 0.2 m/s (40 ft/min). Voltage output. Optimized for clean rooms and laminar flow monitoring.

Detects condensation on pipes, ducts and other surfaces before the condensation actually occurs.

High accuracy measurements of relative humidity and temperature in demanding climate control applications.

A compact humidity and temperature probe with excellent price/performance ratio, optimized for OEM applications.

Wall mounted, measuring range from -40 to 158°F, passive or active outputs, ±0.54°F accuracy

High precision (+/-2% RH), 0 to 100% RH range, choose either an analog voltage output (0 to 1, 2.5 5 or 10 Vdc), or "E2" digital output; temperature range up to 176°F

Non-saturated salt solution, and are available in sets of five or fifty single-use ampoules, which may be stored indefinitely. The kit consists of a humidity calibration chamber and a choice of E+E Humidity Standard Sets.

Excellent accuracy down to 0.15 m/s (30 ft/min). Optimized for clean rooms and laminar flow monitoring.

Measures RH and Temperature and calculates all other humidity related parameters. Either Modbus or CANopen digital interface. Great for demanding process and climate control such as agriculture, food, pharma, or clean rooms. Accuracy ± (1.3 FS + 0.3 % Reading) %RH for RH ≤90 %

With a compact design, "E2" digital output and M12X1 connector, it makes for easy installation and replacement.

For the measurement of CO2 concentration, relative humidity, temperature, and ambient pressure. The heated versions of the EE872 are suitable for high humidity, condensing environments.

Multi-range, user-configurable, and adjustable pressure ranges, 0 to 4" WC and 0" to 40" WC, with ± 0.5 % accuracy of the full scale. Selectable voltage and current outputs.

ACCURACY: +/- 2.5% RH (10...95% RH). Designed for HVAC, a cost-effective, highly accurate transmitter in a polycarbonate housing.

Handheld meter with interchangeable digital probes for accurately measuring humidity, dew point, temperature, CO2, air velocity and volumetric flow.

With robust enclosure and integrated filter, the EE820 is the perfect solution for hatchers, incubators, greenhouses or life stock barns.

High accuracy measurement of flow and temperature in industrial processes up to 10 bar (145 psi) and 120C (248F). Also ideal as a reference unit for labs and test rigs.