About Druck Adroit Pressure Sensors

<< BACK <<

The ADROIT6200 Pressure Platform:  A High-Performance Pressure Measurement Sensor.
Coupling a Druck silicon pressure sensor core with the latest digital processing capability, ADROIT offers levels of accuracy previously unavailable in a device of this type. The sensor offers gauge, absolute, and differential references, and pressure ranges from 200 mbar (2.90 psi) to 350 bar (5,000 psi). It is packaged in a small, 19 mm diameter, fully welded 316L stainless steel body.  The result is a best in class pressure sensor with superior performance in the harshest environments.

The ADROIT6200:  Digital on the Inside, but Analog on the Outside.
Digital signal processing internally allows for high accuracy performance over temperature, but the final stage of processing converts the signal back into conventional analog outputs (4-20 mA, 0-5 Vdc, etc.) for easy interfacing to existing systems.
Fast ASIC technology ensures response times around 1 millisecond and a quick switch on for pulse power operation. The digital processing also enables the replacement of mechanical adjustment to potentiometers with automatic calibration adjustment using an App.

The ADROIT6200:  Superior Accuracy Over Temperature.
At least 5 times and up  to 22.5 times better than other Druck pressure sensors with analog outputs, such as the UNIK5000 or the UNIK5800/5900 Pressure Sensor Platforms.
You have a choice of two accuracy options (as a percentage of Full Scale):
  • +/-0.2% (Improved)
  • +/-0.1% (Premium)
Accuracies include all errors: 
  • Zero and span setting errors
  • Non-Linearity Hysteresis & Repeatability
  • Thermal error over -20 to +80 °C or -40 to +125 °C, depending on the temperature compensation selected (TB or TD), respectively.

ADROIT6200 Verses Other Druck Pressure Sensor Platforms (with analog outputs)

Product Family ===>  ADROIT6200 UNIK5000 UNIK5800/5900
Sensor Electronics ===> 
Digital
Analog
Analog

Outputs ===>

 

 

 

2:  4-20 mA (2-wire)

 

4:  0-5 Volts (3-wire)

5:  Configurable Volt (3-wire)

 

 

 

 

0:  mV Passive (4-wire)

1:  mV Linearised (4-wire)

2:  4-20 mA (2-wire)

3:  0-5 V (4-wire)

4:  0-5 Volts (3-wire)

5:  Configurable Volt (3-wire)

6:  0-10 V (4-wire)

7:  0.5-4.5 V Ratiometric (3-wire)

8:  Configurable (4-wire)

9:  Configurable (3-wire)


    0:  mV Passive (4-wire)

    1:  mV Linearised (4-wire)

    2:  4-20 mA (2-wire)

    3:  0-5 V (4-wire)

    4:  0-5 Volts (3-wire)

    5:  Configurable Volt (3-wire)

    6:  0-10 V (4-wire)

     

     

     

     

     

    Temperature Comp Range ===>

     

     

     

     • TB -20 to +80°C (-4 to +176°F)

     

    • TD -40 to +125°C(-40 to +257°F)

    • TA:  -10 to +50°C (+14 to +122°F)

    • TB:  -20 to +80°C (-4 to +176°F)

    • TC:  -40 to +80°C (-40 to +176°F)

    • TD: -40 to 125°C(-40 to +257°F)

    • TA:  -10 to +50°C (+14 to +122°F)

    • TB:  -20 to +80°C (-4 to +176°F)

    • TC:  -40 to +80°C (-40 to +176°F)

    • TD: -40 to 125°C(-40 to +257°F)

     

    Accuracy ===> 

    (NLH&R at 23°C)

     

    A2:  ±0.04 BSL (Improved)

    A3:  ±0.02 BSL (Premium)

    A1:  Industrial: ±0.2% FS BSL

    A2:  Improved: ±0.1% FS BSL

    A3:  Premium: ±0.04% FS BSL

    A1:  Industrial: ±0.2% FS BSL

    A2:  Improved: ±0.1% FS BSL

    A3:  Premium: ±0.04% FS BSL


    Total Accuracy 
    ===>

    (NLH&R, zero & span setting, and Thermal Error over Compensated  Temperature Range)

     

     

     

    ±0.20 FS (Improved)
    TB or TD Temp Comp

    ±0.10 FS (Premium)
    TB Temp Comp only

    (For the selected temperature compensated range, TB or TD).

    • TA:  -10 to +50°C (+14 to +122°F):
    ±0.75% FS TEB (Industrial)
    ±0.50% FS TEB (Improved, Premium)
    --------------------
    • TB:  -20 to +80°C (-4 to +176°F):

    ±1.5% FS TEB (Industrial)
    ±1.0% FS TEB (Improved, Premium)

    --------------------

    • TC:  -40 to +80°C (-40 to +176°F):
    ±2.25% FS TEB (Industrial)
    ±1.5% FS TEB (Improved, Premium)

    --------------------

    • TD:  -40 to +125°C (-40 to +257°F):
    ±2.25% FS TEB (Industrial)
    ±1.5% FS TEB (Improved, Premium)

    • TA:  -10 to +50°C (+14 to +122°F):
    ±0.75% FS TEB (Industrial)
    ±0.50% FS TEB (Improved, Premium)
    --------------------
    • TB:  -20 to +80°C (-4 to +176°F):

    ±1.5% FS TEB (Industrial)
    ±1.0% FS TEB (Improved, Premium)

    --------------------

    • TC:  -40 to +80°C (-40 to +176°F):
    ±2.25% FS TEB (Industrial)
    ±1.5% FS TEB (Improved, Premium)

    --------------------

    • TD:  -40 to +125°C (-40 to +257°F):
    ±2.25% FS TEB (Industrial)
    ±1.5% FS TEB (Improved, Premium)

     

    Hazardous Approvals ===>

    H0:  None

    H0:  None

    H1:  IECEx/ATEX Intrinsically Safe ‘ia’ Group IIC

    H2:  IECEx/ATEX Intrinsically Safe ‘ia’ Group I

    H6:  FM (C & US) Intrinsically Safe ‘ia’ Group IIC/ABCD

    HA:  IECEx/ATEX Intrinsically Safe ‘ia’ Groups I/IIC [H1 + H2]

    HS:  IECEx/ATEX/FM (C & US) Intrinsically Safe ‘ia’ Groups IIC/ABCD [H1 + H6]

    J1:  IECEx/ATEX/NEPSI Intrinsically Safe ‘ia’ Group IIC

    JA:  INMETRO Intrinsically Safe ‘ia’ Group IIC

    JB:  INMETRO Intrinsically Safe ‘ia’ Group I JF:  INMETRO Intrinsically Safe ‘ia’ Group I/IIC [JA + JB]

    H0:  None

    H1:  IECEx/ATEX Intrinsically Safe ‘ia’ Group IIC

    H2:  IECEx/ATEX Intrinsically Safe ‘ia’ Group I

    H3:  IECEx/ATEX Protected by Enclosure Group IIIC

    H4:  IECEx/ATEX Flameproof Group IIC

    H7:  FM (C & US) Dust Ignition Proof, Groups IIIC/EFG

    H8:  FM (C & US) Flameproof/Explosion Proof, Groups IIC/ABCD

    HA:  IECEx/ATEX Intrinsically Safe ‘ia’ Groups I/IIC [H1 + H2]

    HT:  IECEx/ATEX/FM (C & US) Flameproof/Explosion Proof Groups IIC/ABCD [H4 + H8]