EE776 Insertion Thermal Mass Flow Meter - DESCRIPTION

EE776 Insertion Thermal Mass Flow Meter - DESCRIPTION  
by E+E Elektronik

The EE776 Flow Meter set new standards in terms of safety and easy assembly. The patented non-return protection combines three functions in one device: 

Non-return protection
The probe can only be moved in one direction during installation; it cannot return at all, even if it is released.

Seal
By means of an encapsulated O-ring, the pressurized gas cannot leak during probe mounting.

Probe positioning
The precise positioning with respect to immersion depth and orientation is easy to perform, guaranteeing accurate measurement results.

An optional ½" ball valve enables the installation and removal of the probe without interruption of the gas flow. Every EE776 flow meter undergoes a precise factory calibration procedure at a pressure of 9 bar (130 psi). The corresponding calibration certificate is included in the standard scope of supply.

EE776 features two outputs which can be configured as analog (current or voltage), alarm or pulse output for consumption metering. The EE776 flow meter is available with an additional MODBUS RTU or M-BUS (Meter-Bus) interface.