TEK-CLAMP 1200A-100F1 Wall Mount Ultrasonic Flowmeter - SPECIFICATIONS
TEK-CLAMP 1200A-100F1 Wall Mount Ultrasonic Flowmeter - SPECIFICATIONS
by Tek-Trol
MATERIAL MEASURED: Virtually all commonly used clean liquids are measurable, and liquids with a small number of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 20,000ppm. However, liquids should contain no or minor air bubbles for best results.
Service | Compatible Liquids | ||
Parameters | Specifications | ||
Main Unit | Accuracy | ±1% of Reading | |
Velocity | ±0.03 to ±100 ft/s (±0.01 to ±30m/s) | ||
Repeatability | 0.2% | ||
Measurement Period | 0.5 Seconds | ||
Measurement Principle | Transit-time measurement principle | ||
Display | LCD with backlight. 2 x 20 letters | ||
Output | 100F1 | Modbus RS485, 4-20 mA, Pulse | |
Input | Two three wire system PT100 platinum resistor input loop. For BTV process monitoring | ||
Other Functions | Automatically stores the memory of the positive, negative, net totalizer flow rate and heat quantity of the last 512 days, 128 months, 10 years | ||
Power | 100F1 | 85 to 264VAC or 8 to 36VDC | |
Power Consumption | Less than 1.5W | ||
Environment Temperature | -22 °F to 176 °F (-30 °C to 80 °C) | ||
Environment Humidity | 85% RH | ||
Protection Class | IP65 (Tek-Clamp 1200A-100F1) | ||
Transducers | Clamp-On | S2-type: for pipe size ½” to 4” M2-type: for pipe size 2” to 28” HS-type: for pipe size ½” to 4” HM-type: for pipe size 2” to 28” 1200A-L2: 12” to 200” 1200A-IM: 3” to 7” 1200A-IL: 3” to 12” | |
Protection Class | IP68, can work in water with depths less than 10’ (3m) | ||
Process Temperature | -40 °F to 320 °F (-40 °C to 160 °C) | ||
Pipe | Pipe Material | All metals, most plastics, fiberglass, etc. | |
Pipe Size | ½” to 28” (15mm to 700mm) | ||
Pipe Straight Run | More than 10D for upstream, more than 5D for downstream, , where D is pipe diameter. |