Service |
Compatible Liquids |
|
Parameters |
Specifications |
Main Unit |
Accuracy |
±1% of Reading |
Velocity |
±0.03 to ±100 ft/s (±0.01 to ±30m/s) |
Repeatability |
0.2% |
Measurement Period |
0.5 Seconds |
Measurement Principle |
Transit-time measurement principle |
Display |
LCD with backlight. 2 x 20 letters |
Output |
100F1 |
Modbus RS485, 4-20 mA, Pulse |
100M |
Modbus RS485, 4-20 mA, Pulse |
100EXP |
Modbus RS485, 4-20 mA, Pulse |
100H |
None |
Input |
Two three wire system PT100 platinum resistor input loop. For BTV process monitoring |
Other Functions |
Automatically stores the memory of the positive, negative, net totalizer flow rate and heat quantity of the last 512 days, 128 months, 10 years |
Power |
100F1 |
85 to 264VAC or 8 to 36VDC |
100M |
8 to 36VDC |
100EXP |
8 to 36VDC |
100H |
Rechargeable nickel metal hydride battery |
Power Consumption |
Less than 1.5W |
Environment Temperature |
-22 °F to 176 °F (-30 °C to 80 °C) |
Environment Humidity |
85% RH |
Protection Class |
IP65 (Tek-Clamp 1200A-100F1) IP65; Class I Div II (Tek-Clamp 1200A-100EXP) IP57 (Tek-Clamp 1200A-100M and 1200A-100H) |
Transducers |
Clamp-On |
S2-type: for pipe size ½” to 4” M2-type: for pipe size 2” to 28” HS-type: for pipe size ½” to 4” HM-type: for pipe size 2” to 28” 1200A-L2: 12” to 200” 1200A-IM: 3” to 7” 1200A-IL: 3” to 12” |
Protection Class |
IP68, can work in water with depths less than 10’ (3m) |
Process Temperature |
-40 °F to 320 °F (-40 °C to 160 °C) |
Pipe |
Pipe Material |
All metals, most plastics, fiberglass, etc. |
Pipe Size |
½” to 28” (15mm to 700mm) |
Pipe Straight Run |
More than 10D for upstream, more than 5D for downstream, , where D is pipe diameter. |