Tek-Flow Mass 1300D Series Steam Quality Flowmeter - SPECIFICATIONS
Tek-Flow Mass 1300D Series Steam Quality Flowmeter -
SPECIFICATIONS
by Tek-Trol
Performance Specifications | ||||
Mass Flow Rate accuracy for Dry Gas/Steam based on 50-100% of pressure range. | ||||
Accuracy | Multi Parameter Flo Mass Meter | |||
---|---|---|---|---|
Process Variables | Liquids | Dry Gas/Steam | Wet Gas/Steam | |
Volumetric Flow Rate | ± .7% of Rate | ± 1.5% of Rate | ± 3% of Rate | |
Mass Flow Rate | ± 1% of Rate | ± 1% of Rate | 5% to 10% of Reading* | |
Temperature | ± 2°F (± 1°C) | ± 2°F (± 1°C) | ± 2°F (± 1°C) | |
Pressure | ± .3% of Full Scale | ± .3% of Full Scale | ± .3% of Full Scale | |
Calculated Density** | ± .3% of Reading | ± .5% of Reading | N/A | |
Predicted Density*** | ± .75% of Reading | ± 1% of Reading | ± 4% of Reading | |
Steam Quality | N/A | ± 5% of Reading | ± 5% of Reading | |
* Depending on percentage of liquid content & velocity ** Calculated density is performed with a known fluid temperature & pressure *** Predicted density is a function inherent to the combined technologies of vortex and differential pressure flow metering | ||||
Repeatability | Mass Flow Rate | ± .2% of rate | ||
Volumetric Flow Rate | ± .1% of rate | |||
Temperature | ± .2°F (± .1°C) | |||
Pressure | ± .05% of full scale | |||
Density | ± .1% of reading | |||
Stability Over 12 Months | Mass Flow Rate | ± .2% of rate | ||
Volumetric Flow Rate | ± negligible | |||
Temperature | ± .9°F (± .5°C) | |||
Pressure | ± .1% of full scale | |||
Density | ± .1% of reading | |||
Response Time | Adjustable from 1 to 100 seconds |